Erweka Granulator Model FCSM
Rate listing info and photo quality Why?

Not rated yet
Listing #298182

Erweka Granulator Model FCSM


€4,300.00 Seller's Acceptable Currency

All offers are submitted in Seller's Acceptable Currency

Equipment Description:

  • Erweka Model FCSM Oscillating Granulator
  • DESCRIPTION: Oscillating granulator designed for the reduction from a granular product to a specific size distribution.
    Erweka's equipment is ideal for small scale production in the pharmaceutical, chemical and cosmetic industries.
    The design is compact and economical.
    Approximate capacity is variable depending on product and screen size.
    The granulator operates on the oscillating rotor principle by compressing the granules through a sieve of a predetermined size.
  • SECTORS OF USE:
    Pharmaceutical, chemical, cosmetics, food, dietary, medical devices, manufacturing.
  • MAIN FEATURES:
    Mounted on a platform base with casters for mobility. Painted steel base frame.
    All parts coming into contact with the product are made of stainless steel.
    Simple and quick cleaning without particular machine tools.
    This equipment can be tailored to an extremely wide range of applications and is ideal especially for resulting a uniform granular product of the desired particle size and most importantly without the risk of crushing the granules into powder.
    Changeover from product-to-product is simple and rapid.
  • TECHNICAL DATA:
  • N1: 900 rpm
  • N2: 414 rpm

  • Disclaimers:

    This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in Italy.


    The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

    Equipment Specifications:

    ManufacturerErweka
    ModelFCSM
    Serial Number22275
    Estimated Shipping Weight150 KGS
    Length1200 MM
    Width750 MM
    Height1500 MM
    Frequency50/60 HERTZ
    Recommended Packaging FormPALLET

    Why we recommend inspection Why we recommend inspection Print Version Print Version Conversion Tools Conversion Tools
    Currency Calculator Currency Calculator Email this page to a colleague Email this page to a colleague


    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson & Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, PROGITEC SRL and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, PROGITEC SRL, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and PROGITEC SRL
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson &Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, PROGITEC SRL and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, PROGITEC SRL, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and PROGITEC SRL
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    I acknowledge these conditions and would like to proceed with a preliminary offer