Equipment Description:

  • Bausch Stroebel Ampoule Filling Line
  • Type: AWU8000-DST2247-AFV4015
  • Year: 1985
  • Complete ampoule line for open ampoules
  • Includes:
  • Washing machine AWU 8000,washing temperature max. 85°C
  • Recirculation system UST
  • Sterilization tunnel DST 2247
  • Filler and closing AFV4015 with laminar flow
  • Production speed: 1,000 – 12,000 ampoules/hr depending on the ampoule dimension
  • Pre heating area , sterilization area 310 °C , cooling area , LT unit , register at 6 channels AFV 4015
  • Filling range 1-200 ml with gas closure
  • Ampoule size diameter 10-23 mm ,height max. 140 mm according of the formats
  • 4 filling /closing stations
  • Formats for ampoule 1-2-5-10 ml with 4 rotative pumps (AISI316L) installed on the machine

  • Disclaimers:

    This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in Italy.

    This equipment is subject to a removal and loading charge.

    The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

    Any license associated with this equipment is non transferable.

    Equipment Specifications:

    ManufacturerBausch + Strobel
    Year1985
    Estimated Shipping Weight0 LBS
    Length0 IN
    Width0 IN
    Height0 IN
    Voltage230/460 VOLTS
    Frequency50/60 HERTZ



    Why we recommend inspection Why we recommend inspection Print Version Print Version Conversion Tools Conversion Tools
    Currency Calculator Currency Calculator


    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson & Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, International Trading Italia - Milan and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, International Trading Italia - Milan, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and International Trading Italia - Milan
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson &Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, International Trading Italia - Milan and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, International Trading Italia - Milan, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and International Trading Italia - Milan
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    I acknowledge these conditions and would like to proceed with a preliminary offer