Equipment Description
-The AU680 intuitive graphical user interface includes: • Sample tracking • Patient statistics • User-customized menu • Color alerts to highlight system operating conditions -AU-proven reliability enables greater uptime with quick and easy parts replacement • No tools required • No more than three steps, no longer than 60 seconds, for parts such as sample and reagent probes, mixers and syringes • Online help videos guide the operator on proper technique when performing maintenance procedures and parts replacement, which enables greater system uptime - New analytical horizons • Handling of 3-shot reagents - Plug and play calibration via 2D barcode • Minimized reagent volumes • Eliminates need for multiple calibrators • Applies to C3, C4, Transferrin and ASO - Sample feeder • Positive sample identification to eliminate any sample mix ups • Beckman Coulter flexible racks to handle all commonly used tube sizes in parallel • Barcoded racks to define different sample materials or other sample specifics • 150 samples on board at any time for long walk away • Reflex testing • Priority re-run lane - Refrigerated reagent compartments • Real workstation consolidation with up to 60 different analytes in parallel • Ready to use liquid stable reagents • Automatic bottle switch capabilities • Advanced calibration • Liquid detection and remaining test number calculation - Washing station • High tech wash station to ensure a valid diagnostics • Two different detergents to prevent any carry over • Four fold water cleaning followed by a separate drying step to gain optimum system performance - Mixer • High precision mixer station to ensure excellent reaction conditions • Standardized mixing procedures across the whole range of analyzers • Different mixer positions for individual reaction steps - Cuvettes wheel • Non disposable quartz cuvettes • Software driven carry over elimination • Total reaction volume as small as 120 µl • Environmental friendly - ISE unit • High quality ISE for Na, K and Cl • 6 months shelf life • 18 months shelf life for reference electrodes • 600 tests/hour (if ISE mode only) • Same technology across the whole range of analyzers - Sample probe • Sample volume as small as 1.6 µl • Clot detection • Crash prevention • Sampling frequency of 4.5 seconds - STAT sample rotor • Dedicated STAT rotor with 22 positions and integrated barcode reader • Full STAT capabilities during routine operation • Refrigerated area for calibrators and controls • Combined routine and emergency work area - Reagent probes • Tact frequency 4.5 seconds • Reagent volume as small as 15 µl • Liquid detection • Calculation of remaining tests/vial Analytical system Fully automated, random access chemistry system with STAT capability Analytical principle Spectrophotometry and potentiometry Analytical types Endpoint, rate, fixed point and indirect ISE Analytical methods Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE Simultaneously processed analytes 60 photometric tests + 3 ISE Throughput 800 photometric tests/hour; up to 1,200 with ISE Sample types Serum, urine, whole blood (HbA1c), other 1, other 2 Sample feeder Racks with 10 samples each (bar codes on primary tubes and on racks); capacity of 150 samples; continuous loading Sample tubes In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm STAT samples Up to 22 positions for STAT samples, bar-coded primary tubes Sample volume 1–25 μL in 0.1 μL increments (1–25 μL for repeats) Reagent supply 60 positions for R1, 48 positions for R2; (refrigerated 4–12 °C), handling of 3-shot reagents Reagent volume R1: 15–250 μL; R2: 15–250 μL; (in 1 μL increments) Total reaction volume 120–425 μL Reaction cuvette Quartz cuvettes Reaction time Up to 8 minutes, 40 seconds Reaction temperature 37 °C Mixing method With rotating paddles after dispensing sample and reagent Photometry system Direct assay through the reaction cuvette (0 – 3.0 OD) mono and bichromatic measurements possible Wavelength 13 different wavelengths between 340 – 800 nm Cuvette cleaning Comprehensive cleaning with detergents Calibration Autocalibration, cooled calibrator positions; master calibration established by two-dimensional bar code of the reagent bottle (>3-point calibration) Quality control Auto QC, cooled QC positions Test requisition Individual and profile test requisition via on line, mouse, functions keys or touch screen Safety Clot detection and crash prevention for sample and reagent dispenser Online Full uni- and bidirectional communication possible Software Windows XP® Data Storage Sample number 100,000 samples. Reaction Data 200,000 tests Dimensions (W x H x D) mm ANL 1,950 x 1,280 x 1,000 Power supply 200 V; 208 V; 220 V; 230 V; 240 V; 50 Hz; 60 Hz/3.8 KVA

Specifications:
Standard
Metric
Manufacturer Name
Beckman Coulter
 

Year:
2018
2018

Serial Number:
2018096696
2018096696

CE Marked:
YES
YES

Model:
AU680
AU680

Voltage:
200-240 VOLTS
200-240 VOLTS

Frequency:
50-60 HERTZ
50-60 HERTZ

Phase:
3+1
3+1

Throughput Capability:
800 tests/hour
800 tests/hour

Sample Capacity:
150 samples
150 samples


Dimensions:
Standard
Metric

Overall:
39.37 x 76.77 x 50.39 in - 1166.00 LBS
1000 x 1950 x 1280 MM - 528.90 kg

Disclaimer

This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in

West Lothian

This equipment is subject to a removal and loading charge.


The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

Please be aware that weights and dimensions of equipment provided on EquipNet’s listings are estimates and can vary from actual weights and size. Sellers estimates are often not precise especially when equipment was installed versus prepped for shipment. As such, please do not fully rely on the accuracy of this information in EquipNet’s listings for shipping quotes and/or user size requirements.