Listing# 762049

Cannabis Testing: Thermo Scientific TSQ XL GCMSMS for analyzing Residual Pesticides, Terpenoids, and


Seller's Acceptable Currency:

$69,000.00 USD

Make An Offer

Location:  North America

Level of Removal:  

Why we recommend inspection

*All offers are submitted in Seller’s Acceptable Currency

Don't see what you're looking for? We'll find it for you




Equipment Description

This Thermo Scientific TSQ XL GCMSMS is in excellent condition and it is used for cannabis testing, specifically trace-level analysis of residual pesticides and mycotoxins.

The TSQ Quantum XLS and TSQ Quantum GC are members of the TSQ Quantum™ family of Thermo Scientific mass spectrometers.

System Includes:
  • TSQ Quantum
  • XLS MS/MS
  • Trace GC Ultra
  • TriPlus Autosampler
  • Cables and connectors
  • Computer

In a typical analysis, an autosampler (AS) introduces a sample into the gas chromatograph (GC). The GC separates the sample into its various components. The components elute from the GC and pass into the mass spectrometer where they are analyzed.

The mass spectrometer’s triple-stage mass analyzer performs either one or two stages of mass analysis:
• The mass spectrometer is operated as a conventional mass spectrometer with one stage of mass analysis. The ion source ionizes the sample and the ion products are subjected to mass analysis in the first-rod assembly. The second and third-rod assemblies transmit the resulting mass-selected ions to the ion detection system.
• The mass spectrometer is operated as a tandem mass spectrometer with two stages of mass analysis. The ion source ionizes the sample and the ion products are mass analyzed by the first-rod assembly. In this case, however, mass-selected ions exiting the first-rod assembly collide with an inert gas in the second-rod assembly and fragment to produce a set of ions
known as product ions. (A chamber called the collision cell surrounds the second-rod assembly. The collision cell can be pressurized with an inert gas.) The product ions undergo further mass analysis in the third rod assembly to detect selected ions.

Two stages of mass analysis yield far greater chemical specificity than a single-stage can achieve, because of the system’s ability to select and determine two discrete but directly related sets of masses. In the first stage of mass analysis, you can use the mass spectrometer to elucidate the structures of pure organic compounds and the structures of the components within mixtures.



Specifications:
Standard
Metric

Manufacturer Name
Thermo Scientific
 

Model:
TSQ Quantum
TSQ Quantum


Disclaimer

This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in

the USA.

This equipment is subject to a removal and loading charge.


The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

Please be aware that weights and dimensions of equipment provided on EquipNet’s listings are estimates and can vary from actual weights and size. Sellers estimates are often not precise especially when equipment was installed versus prepped for shipment. As such, please do not fully rely on the accuracy of this information in EquipNet’s listings for shipping quotes and/or user size requirements.

Any license associated with this equipment is non-transferable.

Customers who viewed this item also viewed this