Listen Nummer 722090

Massenspektrometer Waters Synapt G1


Seller's Acceptable Currency:

$40,000.00 USD

Machen Sie ein Angebot

Standort:  PA, USA

Niveau Entfernen:  

Wir empfehlen eine Inspektion weil

*All offers are submitted in Seller’s Acceptable Currency

Don't see what you're looking for? We'll find it for you

Click here to view the sales agreement.





Maschinen und Geräte Beschreibung
Refurbished Waters SYNAPT G1 HDMS Q-TOF Mass Spectrometer with Software
Title:
Refurbished Waters SYNAPT G1 HDMS Q-TOF Mass Spectrometer with Software!

Overview:
This system was fully PM’d and set up by certified engineers. Inspection and single sample testing is optional for interested buyers. Attached is a full report of the instrument testing and reporting after the preventative maintenance was completed. This instrument is in great condition!

Included:
• Waters Synapt G1 HDMS Mass Spectrometer
• Edwards XDS 35i pump
• All tubing and connections
• Computer with software (no license)

Detailed Description:

The Waters SYNAPT HDMS Q-TOF Mass Spectrometer (QTOF LCMSMS MSD G1 High Definition Mass Spectrometry Quadruple Time of Flight ) is designed for leading researchers working at the limits of conventional mass spectrometry capabilities who need to further characterize and define their samples, Waters SYNAPT HDMS System offers unique, enabling functionality. Waters SYNAPT HDMS System enables the analysis of samples differentiated by size and shape, as well as mass, to deliver increased specificity and sample definition beyond that achievable by conventional mass spectrometers. System Includes:

TOF Mass Resolution in Positive Ion
a) V Mode: 10,000 measured on the (M + 6H)^6+ isotope cluster from bovine insulin (m/z 956)
b) W Mode: 17,500 measured on the (M + 6H)^6+ isotope cluster from bovine insulin (m/s 956)
TOF Mass Resolution in Negative Ion
a) V Mode: 10,000 measured on the (M - 4H)^4- isotope cluster from bovine insulin (m/z 1431)
b) W Mode: 17,500 measured on the (M - 4H)^4- isotope cluster from bovine insulin (m/z 1431)
Positive Ion MS Sensitivity
a) V Mode: The peak at m/z 556 from a solution of 50 pg/µL leucine enkephalin in 50/50 acetonitrile/water + 0.1% formic acid, infused at a flow rate of 5 µL/min, will have an intensity of greater than 1,700 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin) and the mass range will be set to 1,000 Da.
b) EDC: The peak at m/z 556 from a solution of 10 pg/µL leucine enkephalin in 50/50 acetonitrile/water + 0.1% formic acid, infused at a flow rate of 5 µL/min, will have an intensity of greater than 2,000 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin), with sensitivity set to a maximum at 556 Da.
Negative Ion MS Sensitivity:
V Mode: The peak at m/z 503 from a solution of 500 pg/µL raffinose in 70/30 acetonitrile/water (no additives), infused at a flow rate of 5 µL/min, will have an intensity of greater than 1,800 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin), and the mass range will be set to 1,000 Da.
Positivt Ion MS/MS Sensitivity
V Mode: Using a [Glu]-Fibrinopeptide B solution of 100 fmol/µL, at a flow rate of 5 µL/min and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the most intense y" sequence ion from the MS/MS spectrum of the doubly charged precursor ion (785.8 Da) will be greater than 130 counts per second. This will correspond to a signal to noise ratio of greater than 50:1 (after a 3x9 smooth) on the most intense y" sequence ion, for a 1 second scan. The instrument mass range will be set to 2,000 Da.
Negative Ion MS/MS Sensitivity
V Mode: Using a solution of 500 pg/µL raffinose in 70/30 acetonitrile/water, at a flow rate of 5 µL/min and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the fragment ion at 179.1 Da in the MS/MS spectrum of the precursor ion at 503.2 Da will be greater than 130 counts per second. The instrument mass range will be set to 1,000 Da.
Mass Scale Calibration Accuracy
The mass measurement accuracy of the instrument in V-mode, using an internal lockmass, is such that the RMS error between the measured and the accepted masses of peaks which have sufficient intensity, and are free from interference from other masses, will be less than 2 ppm over the range of 150-900 Da.
Mass Measurement Accuracy
The mass measurement accuracy of the instrument, in W-mode, will be better than 2 ppm RMS, based on 10 consecutive repeat measurements of the [M + Na]^+ ion of raffinose (m/z 527.1588), using the [M + H]^+ ion of leucine enkephalic (556.2771) as the LockSpray lockmass. Analyte lockmass peaks must have sufficient intensity and be free of interference from other masses.
Mass Range
The TOF mass range is 20 - 100,000 Da in V-mode, and 20 - 26,500 Da in W-mode.
The quadrupole mass range in non-resolving mode is 20 - 16,000 Da for a 4,000 Da quadrupole, and 20 - 32,000 Da for an 8,000 Da quadrupole.

Note: Licenses for Waters’ software products are not transferable. Any customer who purchases Waters products are advised that in order to hold a valid license to use the Waters’ software, they must purchase a license and appropriate Application Manager directly from Waters.


Spezifikationen:
Standard
Metrik

Manufacturer Name
Waters
 

Jahr:
2008
2008

Seriennummer:
UAA 130
UAA 130

Mit CE-Zeichen:
YES
YES

Modell:
Synapt G1
Synapt G1

Typ der Massen-Spezifikation:
Q-TOF
Q-TOF

Spannung:
200-240 VOLTS
200-240 VOLTS

Frequenz:
50/60 HERTZ
50/60 HERTZ

Phase:
1
1

Strom:
10 AMPS
10 AMPS

Empfohlene Paketform:
CUSTOM
CUSTOM


Dimensions:
Standard
Metrik

Overall:
65 x 36 x 70 IN - 750 LBS
1651,00 x 914,40 x 1778,00 mm - 340,20 kg


Disclaimer

Dieser Posten wird im Ist-Zustand am gegenwärtigen Standort veräußert. Wir empfehlen, dass Sie für Ihre eigene Inspektion einen EquipNet-Vertriebsmitarbeiter kontaktieren. Der Posten befindet sich in

PA

This equipment is subject to a removal and loading charge.

Please note The seller of this equipment requires the buyer to accept a sales agreement. Click here to view the sales agreement.


Die für diese Ausrüstung bereitgestellte Beschreibung stimmt EXAKT mit dem überein, was Sie erhalten, wenn Sie sich für den Kauf dieses Listings entschieden haben. Jedwede Posten, die nicht in der Beschreibung enthalten sind, aber in der optischen Darstellung dieses Listings erscheinen, werden in den Verkauf nicht einbezogen. Fotos und Videos werden ausschließlich zu Referenzzwecken bereitgestellt bzw. um einen generellen Eindruck des Zustands gewinnen zu können.