NO. de listado 411066

Analizador para Immunoensayo Axon Instruments PatchXpress 7000A


Divisa aceptada por el vendedor:

£14,000.00 GBP

Realizar Oferta

Ubicación:  Reino Unido

Nivel de Remoción:  

Por qué recomendamos una inspección

*Todas las ofertas se deben ingresar en la divisa aceptada del vendedor

¿No encuentra lo que está buscando? Lo encontramos por usted.

Please be advised that there will be a delay in the availability of this equipment. This is due to safety protocols enacted by this facility in relation to Covid-19.




Descripción del equipo
Axon Instruments PatchXpress 7000A Automated Patch Clamp System

  • 100-240V, 50/60Hz, 8.5A
  • Manaul included
  • Fully automated 16 channel patch clamping system for mammalian cells
  • Largest reservoir for extracellular solution in combination with the independent wash station enables virtually unlimited washout duration at any point of the experiment: let the cell set the pace, not the instrument.
  • Rapid fluid exchange for capturing even the fastest ligand-gated ion channels.
  • Automated Pressure Control enables reproducible and reliable seal formation and whole-cell recordings.
  • Asynchronous Control applies pressure and suction independently to each chamber, depending on the individual membrane parameters.
  • Multiclamp 700 Amplifier technology inside „Ÿ proven technology ensures highest data quality.
    Independent wash station for individual washout of each recording chamber without tying up the pipettor.
  • True gigaseal technology delivers data of a quality equivalent to the gold standard of conventional patch clamp.
  • Disposable pipette tips minimize cross-contamination by compound carryover.
  • Multiple compound additions minimize loss of potency due to nonspecific binding to pipette tip, excess cells, and recording chamber.
  • Mix during compound pickup and delivery further reduces nonspecific binding for very "sticky" compounds.
  • Script-controlled procedures for online decision making during the experiment.
  • Assay Development and Screening Modes give you the choice of user interaction or maximal automation.
  • Membrane test between sweeps continuously monitors cell health and controls further progress of the experiment to avoid compound wastage.
  • Procedure Loops facilitate setting up concentration-response procedures.
  • Similar styling to the pCLAMP Software user interface makes the PatchXpress Commander software easy to use and understand for the vast majority of all electrophysiologists - those who have used pCLAMP Software.
  • Data management and analysis software included
  • Preloaded programs are: Microsoft Windows XP, PatchXpress Commander, DataXpress client and importer, pClamp softare (includes Clampfit), AxoTrace.
  • With Edwards RV8 vacuum pump
  • With Dell tower PC, monitor, keyboard, and mouse.

Especificaciones:
Estándar
Métrico
Fabricante
Axon Instruments
 

Número de serie:
19181224
19181224

Modelo:
PatchXpress 7000A
PatchXpress 7000A

Empaque recomendado:
PERSONALIZADO
PERSONALIZADO


Dimensiones:
Estándar
Métrico

Ver todas las dimensiones

Artículo #1:
43.31 x 90.55 x 66.93 IN - 1,102.31 LBS
1100.00 x 2300.00 x 1700.00 MM - 500.00 KGS

Artículo #2:
0 x 0.00 x 0.00 IN - 0.00 LBS
0.00 x 0.00 x 0.00 MM - 0.00 KGS

Artículo #3:
0 x 0.00 x 0.00 IN - 0.00 LBS
0.00 x 0.00 x 0.00 MM - 0.00 KGS

Artículo #4:
0 x 0.00 x 0.00 IN - 0.00 LBS
0.00 x 0.00 x 0.00 MM - 0.00 KGS

General:
43.31 x 90.55 x 66.93 in - 1102.30 lb
1100 x 2300 x 1700 MM - 500 KGS

Aviso Legal

Este listado se vende "en el estado que está y en donde se encuentre". Le sugerimos que se comunique con un representante de ventas de EquipNet para programar una inspección. Este artículo se encuentra ubicado en

Europe

Este Listado está sujeto a costos por carga y remoción.


La descripción escrita que se ofrece para este artículo es EXACTAMENTE lo que usted recibirá si decide comprar este listado. Los artículos que no estén en la descripción pero que aparezcan en las representaciones visuales del listado, no estarán incluidos en la venta. Las fotos y videos se ofrecen únicamente como referencia y para dar una idea general de las condiciones del artículo.

Por favor tome en cuenta que el peso y las dimensiones de los equipos que EquipNet proporciona en los listados solo es un aproximado y que puede variar del peso y tamaño real. Los etimados de los Vendedores por lo general no son precisos especialmente cuando se compara el equipo instalado y el mismo equipo prerarado para su envio. Por tal motivo. por favor no se confíe de la exactitud de la información en los listados de EquipNet cuando realice cotizaciones de envío y/o requerimientos del tamaño del usuario.

No es transferible ningúna licencia relaacionada a este equipo.

Clientes que vieron este artículo también vieron