NO. de listado 731294

Bomba de Vacío Edwar QMB1200


Divisa aceptada por el vendedor:

€10,000.00 EUR

Realizar Oferta

Ubicación:  Europe

Nivel de Remoción:  

Por qué recomendamos una inspección

*Todas las ofertas se deben ingresar en la divisa aceptada del vendedor

¿No encuentra lo que está buscando? Lo encontramos por usted.




Descripción del equipo
Edwards QMB1200 Vacuum Pump

Maximum continuous inlet pressure: 1 mbar.
Typical shaft-seal nitrogen flow: 7 slm
Warm-up time: 15 min.
Inlet connection: ISO 160 bolted.
Outlet connection: NW40
Oil capacity:
Coupling cover: 2,4 liter.
Shaft-seal reservoir: 0,13 liter
Gear case: 1,25 liter
Typical cooling water flow : 204 l/h.
Rated motor power: 4,0 kW
Weight : 450 kg.
Peak speed: 940 m3/h.
Displacement: 1435 m3/h.
Ultimate vacuum: 7x10-4 mbar or 5,3x10-3 Torr
Power input at vacuum : 1,7 kW.

Edwards IQ Dry Vacuum Pumps are well-suited for vacuum applications in solar cell manufacturing. Like integrated circuit and flat-panel display manufacturing, solar cell manufacturing depends on a variety of vacuum-based processes, from PECVD (plasma-enhanced chemical vapor deposition) silicon deposition to lamination of the finished module. High pumping speeds and rapid chamber cycling are essential if these processes are to meet the throughput requirements of the solar cell industry. Our rebuilt Edwards IQDP Dry Vacuum Pumps are dependable with benefits that include very lower up front costs, reduced energy consumption and decreased maintenance requirements.

Edwards QMB1200 Technical Data
General QMB1200
Continuous inlet pressure 0 to 1 mbar, 0 to 100 Pa
Maximum outlet pressure 1000 mbar, 1 x 105 Pa
Ambient operating temperature range 5 to 40 °C
Maximum operating humidity 90% RH
Protection degree (as defined by IEC 529) IP44
Recommended oil type Fomblin YVAC 16/6 or Krytox 1514
Electrical Data
Number of phases 3
Supply voltage 200-208 V/380-415 V at 50 Hz
200-230 V/460 V at 60 Hz
Voltage tolerance ±10%, except 208 and 415 V at
50 Hz which are +6% and -10%
Full load current ratings
Supply voltage and frequency 200-208 V 50 Hz 200-208 V 60 Hz 230 V 60 Hz 380-415 V 50 Hz 460 V 60 Hz
QMB1200 Full load (A) 16 16 14.2 8 8
Rating (kW) 4 4 4 4 4
Motor protection thermistors
Type
Reference temperature
Compliant with
Recommended control-unit
Positive temperature coefficient
160 °C
IEC 34-11
To comply with IEC 34-11
Mass (kg) 157
Minimum cooling-water flow (l.h-1) 75
Oil capacity (l)
Coupling-cover
Shaft-seal reservoir
Gear-case
2.4
0.125
1.25
Rotational speed (r.min-1)
50 Hz supply
60 Hz supply
0 to 2900
0 to 3500
Ultimate pressure without
gas-ballast, permanent gases 8 x 10-4 mbar
8 x 10-2 Pa
Pressure differential across pump
determined by the hydrokinetic drive 0 to 90 mbar
0 to 9 x 103 Pa
Recommended backing-pump QDP40 or QDP80
Vacuum connections
Inlet connection
Outlet connection
ISO160 bolted
ISO100 bolted
Cooling-water connections
Inlet connection (BSP)
Outlet connection (BSP)
Hansen quick connect
3/8 inch male
Hansen quick connect
3/8 inch female
Noise data
Continuous A-weighted
sound pressure level (dB(A))


Especificaciones:
Estándar
Métrico
Fabricante
Edwar
 

Año:
2004
2004

Modelo:
QMB1200
QMB1200

Número de serie:
046206386
046206386

Voltaje:
400 VOLTS
400 VOLTS

Frecuencia:
50 HERTZ
50 HERTZ

Fase:
3
3


Dimensiones:
Estándar
Métrico

General:
4.92 x 1.64 x 39.37 ft - 352.74 lb
1.5 x 0.5 x 12 M - 160 KGS

Aviso Legal

Este listado se vende "en el estado que está y en donde se encuentre". Le sugerimos que se comunique con un representante de ventas de EquipNet para programar una inspección. Este artículo se encuentra ubicado en

Europe.

Este Listado está sujeto a costos por carga y remoción.


La descripción escrita que se ofrece para este artículo es EXACTAMENTE lo que usted recibirá si decide comprar este listado. Los artículos que no estén en la descripción pero que aparezcan en las representaciones visuales del listado, no estarán incluidos en la venta. Las fotos y videos se ofrecen únicamente como referencia y para dar una idea general de las condiciones del artículo.

Por favor tome en cuenta que el peso y las dimensiones de los equipos que EquipNet proporciona en los listados solo es un aproximado y que puede variar del peso y tamaño real. Los etimados de los Vendedores por lo general no son precisos especialmente cuando se compara el equipo instalado y el mismo equipo prerarado para su envio. Por tal motivo. por favor no se confíe de la exactitud de la información en los listados de EquipNet cuando realice cotizaciones de envío y/o requerimientos del tamaño del usuario.

No es transferible ningúna licencia relaacionada a este equipo.

Clientes que vieron este artículo también vieron