Waters SYNAPT HDMS Q-TOF Mass Spectrometer

The Waters SYNAPT HDMS Q-TOF Mass Spectrometer ( QTOF LCMSMS MSD G1 High Definition Mass Spectrometry Quadruple Time of Flight ) is designed for leading researchers working at the limits of conventional mass spectrometry capabilities who need to further characterize and define their samples, Waters SYNAPT HDMS System offers unique, enabling functionality. Waters SYNAPT HDMS System enables the analysis of samples differentiated by size and shape, as well as mass, to deliver increased specificity and sample definition beyond that achievable by conventional mass spectrometers.System Includes:
  • Computer & Software
  • Edwards XDS 35i Roughing Pump
  • SYNAPT HDMS Q-TOF MSMS
Optional:
  • ACQUITY UPLC System
  • The SYNAPT HDMS System can operator in two modes: a) TOF mode b) Mobility-TOF mode TOF Mass Resolution in Positive Ion a) V Mode: 10,000 measured on the (M 6H)^6 isotope cluster from bovine insulin (m/z 956) b) W Mode: 17,500 measured on the (M 6H)^6 isotope cluster from bovine insulin (m/s 956) TOF Mass Resolution in Negative Ion a) V Mode: 10,000 measured on the (M - 4H)^4- isotope cluster from bovine insulin (m/z 1431) b) W Mode: 17,500 measured on the (M - 4H)^4- isotope cluster from bovine insulin (m/z 1431) Positive Ion MS Sensitivity a) V Mode: The peak at m/z 556 from a solution of 50 pg/?L leucine enkephalin in 50/50 acetonitrile/water 0.1% formic acid, infused at a flow rate of 5 ?L/min, will have an intensity of greater than 1,700 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin) and the mass range will be set to 1,000 Da. b) EDC: The peak at m/z 556 from a solution of 10 pg/?L leucine enkephalin in 50/50 acetonitrile/water 0.1% formic acid, infused at a flow rate of 5 ?L/min, will have an intensity of greater than 2,000 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin), with sensitivity set to a maximum at 556 Da. Negative Ion MS Sensitivity: V Mode: The peak at m/z 503 from a solution of 500 pg/?L raffinose in 70/30 acetonitrile/water (no additives), infused at a flow rate of 5 ?L/min, will have an intensity of greater than 1,800 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin), and the mass range will be set to 1,000 Da. Positivt Ion MS/MS Sensitivity V Mode: Using a [Glu]-Fibrinopeptide B solution of 100 fmol/?L, at a flow rate of 5 ?L/min and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the most intense y" sequence ion from the MS/MS spectrum of the doubly charged precursor ion (785.8 Da) will be greater than 130 counts per second. This will correspond to a signal to noise ratio of greater than 50:1 (after a 3x9 smooth) on the most intense y" sequence ion, for a 1 second scan. The instrument mass range will be set to 2,000 Da. Negative Ion MS/MS Sensitivity V Mode: Using a solution of 500 pg/?L raffinose in 70/30 acetonitrile/water, at a flow rate of 5 ?L/min and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the fragment ion at 179.1 Da in the MS/MS spectrum of the precursor ion at 503.2 Da will be greater than 130 counts per second. The instrument mass range will be set to 1,000 Da. Mass Scale Calibration Accuracy The mass measurement accuracy of the instrument in V-mode, using an internal lockmass, is such that the RMS error between the measured and the accepted masses of peaks which have sufficient intensity, and are free from interference from other masses, will be less than 2 ppm over the range of 150-900 Da. Mass Measurement Accuracy The mass measurement accuracy of the instrument, in W-mode, will be better than 2 ppm RMS, based on 10 consecutive repeat measurements of the [M Na]^ ion of raffinose (m/z 527.1588), using the [M H]^ ion of leucine enkephalic (556.2771) as the LockSpray lockmass. Analyte lockmass peaks must have sufficient intensity and be free of interference from other masses. Mass Range: The TOF mass range is 20 - 100,000 Da in V-mode, and 20 - 26,500 Da in W-mode. The quadrupole mass range in non-resolving mode is 20 - 16,000 Da for a 4,000 Da quadrupole, and 20 - 32,000 Da for an 8,000 Da quadrupole.     Note: Licenses for Waters’ software products are not transferable. Any customer who purchases Waters products are advised that in order to hold a valid license to use the Waters’ software, they must purchase a license and appropriate Application Manager directly from Waters.


Note: Stock Photos - not exact representation of equipment.

Especificaciones:
Estándar
Métrico
Fabricante
Waters
 

Modelo:
SYNAPT HDMS Q-TOF
SYNAPT HDMS Q-TOF

Tipo de espectrómetros de masa:
Q-TOF
Q-TOF

Empaque recomendado:
6C (6X6X6)
6C (6X6X6)


Dimensiones:
Estándar
Métrico

General:
1 x 1 x 1 IN - 1 Pounds
25.40 x 25.40 x 25.40 mm - 0.45 kg

Aviso Legal

Este listado se vende "en el estado que está y en donde se encuentre". Le sugerimos que se comunique con un representante de ventas de EquipNet para programar una inspección. Este artículo se encuentra ubicado en

North America.

Este Listado está sujeto a costos por carga y remoción.


La descripción escrita que se ofrece para este artículo es EXACTAMENTE lo que usted recibirá si decide comprar este listado. Los artículos que no estén en la descripción pero que aparezcan en las representaciones visuales del listado, no estarán incluidos en la venta. Las fotos y videos se ofrecen únicamente como referencia y para dar una idea general de las condiciones del artículo.

Por favor tome en cuenta que el peso y las dimensiones de los equipos que EquipNet proporciona en los listados solo es un aproximado y que puede variar del peso y tamaño real. Los etimados de los Vendedores por lo general no son precisos especialmente cuando se compara el equipo instalado y el mismo equipo prerarado para su envio. Por tal motivo. por favor no se confíe de la exactitud de la información en los listados de EquipNet cuando realice cotizaciones de envío y/o requerimientos del tamaño del usuario.

No es transferible ningúna licencia relaacionada a este equipo.

Clientes que vieron este artículo también vieron