4.3.2 Function description, mechanical interface
Cooler is designed for a throughput of 400 cups / minute. System consists of two vertical buffers, isolation hood, evaporators and vans. First
buffer contains 24 levels, second one 28. This results in a maximum throughput of 26.5 carriers / minute for the mechanical part of the system. In
spite of cooling equipment is limited to 400 cups / minute.
In feed temperature is between 75°C – 70°C; desired discharge temperature between 25 °C +/- 2° C. Achi evable cooling time is max. 20 min.
In feed level is at 1156 mm; out feed at 775 mm.
Overall height of cooler: approx. 4800 mm
4.3.3 Control interface
Required data (like cooler temperature) for different products is selected by operators by choosing defined recipes at operation panel of the line.
All mal function messages are also shown at operation panel of line control. Cooler itself has no other interfaces than to Gronemeyer machines.
Brief description of functions
4.3.4 Brief description of functions (Gronemeyer Vertical Cooler)
The Vertical Cooler consists of an elevating tower, a lowerating tower and a top conveyor as well as an infeeding and a discharging conveyor.
These components represent the conveying system. Elevating and lowerating tower consists each of two opposing chain drives with two roller
chains each. At these the product taking angled rails are mounted.
On an inserted ceiling on top of the conveying techniques the evaporator units incl. the ventilators are located. These components represent the
internal refrigerating system.
The complete installation is covered by an insulation hood and is situated on a machine basement. Air-conducting metal sheets systematically
guide the air along the products.

Groups of 5 carriers each will arranged on the infeed conveyors. Two groups form a layer within the Vertical Cooler. After 10 carriers have
reached their position in the Vertical Cooler they will be lifted by a pitch of 3” within the elevating tower. The infeed conveyor will be again free for
the next two groups.

In the elevating tower 24 layers fit on top of each other. After a stroke movement the supreme layer will be shifted by the top conveyor from the
elevating to the lowerating tower. Two transfer elements serve for a secure positioning in the second tower.
After the carriers are passed over, they move downwards clocked within the lowerating tower. Here 29 layers fit on top of each other. With the
last clocking the carriers will be positioned onto the discharging conveyor and drive outwards of the Vertical Cooler. Depending on the line’s
situation the discharged carriers will be directed to the Vertical Buffer (see 4.12 and 4.13) for loaded carriers or they return underneath alongside
the infeeding conveyor back in the line.
During the stay into the Vertical Cooler chilled air is blown steadily through the products. The chilling of the air is realized by means of the
refrigerating system on top of the conveying installation. Air-conducting metal sheets assure that the air streams systematically through the
carriers.

Equipment Specifications

Conversion Tools
 StandardMetric
Year2008 
ModelFZ 200 1F 
Serial NumberP0.8 3280-02/ 4500088183 
Capacity Size18.96 lb8.6 KGS
CE MarkedYES 
Temperature RangePRODUCT INFEED 75-70 °C DISCHARGE 25 +/- 2°C DEG CPRODUCT INFEED 75-70 °C DISCHARGE 25 +/- 2°C DEG C
Material of ConstructionPOLYPROPYLENE 
Chamber DimensionsWidth 8.400 mm Depth 3000 mm Height 5000 mm inWidth 8.400 mm Depth 3000 mm Height 5000 mm MM
Voltage400 VOLTS400 VOLTS
Frequency60 HERTZ60 HERTZ
Phase3 
Current8.6 KW8.6 KW
Estimated Shipping Weight16534.50 lb7500 KGS
Estimated Shipping Length314.96 in8000 MM
Estimated Shipping Width118.11 in3000 MM
Estimated Shipping Height196.85 in5000 MM
Disclaimers ▼
This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in Mexico.

This equipment is subject to a removal and loading charge.

The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

Please be aware that weights and dimensions of equipment provided on EquipNet’s listings are estimates and can vary from actual weights and size. Sellers estimates are often not precise especially when equipment was installed versus prepped for shipment. As such, please do not fully rely on the accuracy of this information in EquipNet’s listings for shipping quotes and/or user size requirements.

Any license associated with this equipment is non transferable.