Número do item 923756

Incinerador FireLake P77-3NG-SC8-TC21


Moeda Aceitável de Vendedores:

$57,250.00 USD

Fazer uma oferta

Localização:  North America

Nível de Remoção:  

Por que recomendamos visita aos equipamentos?

*Todas as ofertas são enviadas em moeda dos vendedores

Não encontrou o que você está procurando? Nós podemos encontrar para você





Documentos de Ativo
Descrição do equipamento
NORTHWEST INDUSTRIAL EQUIPMENT INC.: FIRELAKE INCINERATOR - #26700: P77-3NG-SC8-TC21 PURCHASED: $81,800 SPECIFICATIONS: WASTE CHAMBER: CHAMBLER CAPACITY: 2540 lbs. of waste at 33 lbs/cu ft CHAMBER VOLUME: 77 cubic feet DOOR DIMENSION: 30" x 79" HEIGHT TO DOOR: 54" REFRACTORY: 4", 2800°f, 126 lbs/cubic feet JACKET MATERIAL: 3/16” steel HEIGHT TO TOP OF CHAMBER: 55" varies STACK AND SECONDARY: STACK: (3) 18" Dia., 48" Long Steel Cast Lined STACK CAP: (1) 18” Diameter Stainless Steel SECONDARY CHAMBER (1) Aluminized Steel with Refractory Lining BURNERS: MODEL: OIL (3) Beckett SF Oil Burner W/ Flame Safety MODEL: GAS 11/32” (350Kbtu) limiting orifices each lower burners (1) Midco 121 AND (2) Midco 83 w/safety controls OPERATION: Remote Standing Control Box with Temperature Controls & Optional Recording GENERAL: INTERNAL DIMENSIONS: 32" W x 44" H x 83" L (less stack). OVERALL DIMENSIONS (APPROX.), INCLUDING COUNTERBALANCE WEIGHTS, BURNER, STACK AND STACK CAP: 6.7 ft W x 13.5 ft L x 26 ft H ELECTRICAL SERVICE: Standard-115 volt, 60hz, 30 amp, Also available -- 220 volts, 50hz, 15 amp WATER, FRESH (BURN CHAMBER SPRAY): Min. 60 psi at 0.8 gpm GAS SERVICE BASED ON MAX RATING OF THE THREE BURNERS: (ACTUAL BURN IS LESS, FACTORY SETS FLOW AND CONTROL TURNS THEM ON AND OFF): 2,800,000 BTUH (piping sized accordingly) Natural Gas: 7" W.C. (with burners operating) Liquid Propane: 11" W.C. (with burners operating) FUEL OIL SET RATE OF THREE BURNERS: (ACTUAL BURN IS LESS, CONTROL TURNS THEM ON AND OFF): Fuel Oil 3 burners x 3 gph = 9 GPH Burners pumps move (not burn) approx 3x flow in two pipe operation. TOTAL WEIGHT: 18,500 lbs (approximate, varies with features) PAD REQUIREMENTS (MINIMUM): 6’ W x 11’ L x 6” Thick Concrete. PAINT: 1200 degree primer 1200 degree paint CHARGING RATE: PATHOLOGICAL: Approximate 1650 lbs. per charge at 33 lbs/cu ft of typical pathological waste with a BTU/lb rating of 1000. Less pounds for volatile wastes. Chamber may be recharged during burn with proper heat resistant safety attire that protects from flash and heat contact. Allow cool down for ash removal. BURN RATE: Will vary but may range up to 125lb./hr.

Especificações:
Padrão
Métrico
Nome do fabricante
FireLake
 

Ano:
2019
2019

Modelo:
P77-3NG-SC8-TC21
P77-3NG-SC8-TC21


Dimensões:
Padrão
Métrico

Total:
14 x 7 x 8 FT - 18500 LBS
426,72 x 213,36 x 243,84 cm - 8391,60 kg

Aviso Legal

Recomendamos que você entre em contato com a EquipNet para agendar uma visita ao equipamento (19) 3277-1125, vendas@equipnet.com.

North America.

Quaisquer itens que não estão na descrição, mas aparecem nas representações visuais, não serão incluídos na venda. Remoção, desmontagem, embalagem, seguro e frete: custos de responsabilidade do comprador.


Quaisquer itens que não estão na descrição, mas aparecem nas representações visuais, não serão incluídos na venda. Remoção, desmontagem, embalagem, seguro e frete: custos de responsabilidade do comprador. Poderão haver requisitos específicos na execução dos serviços dentro da área do vendedor. Poderá ser obrigatória a realização dos serviços somente por empresas que já são homologadas pelo vendedor.