Listing# 994325

Waters Acquity Classic UPLC System


Seller's Acceptable Currency:

$15,000.00 USD

Make An Offer

Location:  CA, USA

Level of Removal:  

Why we recommend inspection

*All offers are submitted in Seller’s Acceptable Currency

Don't see what you're looking for? We'll find it for you





Asset Documents
Equipment Description
Waters Acquity Classic UPLC System
includes:

Binary Solvent Manager P/N 186015001
Sample Manager P/N 186015006
Column Heater P/N 186015010
PDA Detector P/N 186015026
The Waters ACQUITY UPLC system provides you with reproducible, dependable and data rich results for challenging separations. This UPLC system features a wide range of flow rates, back pressures and linear velocities, with increased throughput with high efficiency so you get the most for your time and resources.

This ultra-performance liquid chromatography system has a unique sub 2 m particle system that offers 3 times the efficiency of a 5 m system with 70% higher resolution. This higher resolution means more information from more samples in less time. The Waters UPLC system can then run separations at a flow rate 3 times faster than HPLC, without a loss in resolution. This self-contained Waters ACQUITY system contains a PDA Detector, sampler manager autosampler, a binary solvent manager, as well as a solvent and waste tray.



Binary solvent manager

The binary solvent manager is a high-pressure pump that moves solvent through the system. It provides steady (pulse-free) solvent flow at analytical flow rates. The binary solvent manager delivers solvent at flow rates of 1 mL/min at 103,421 kPa (1034 bar, 15,000 psi) and up to 2 mL/min at reduced pressures to 62,053 kPa (621 bar, 9000 psi). The binary solvent manager can pump two solvents simultaneously.
Sample manager

The ACQUITY UPLC sample manager injects the samples it draws from microtiter plates or vials onto the chromatographic column. A locating mechanism uses a probe to access sample locations and draw sample from them. In the needle overfill load-ahead mode, the sample manager can perform an injection in approximately 15 seconds. The first injection requires additional overhead time.
The sample manager accepts standard ANSI/SBS footprint plates, 5.03 0.02 inch 3.365 0.02 inch, that conform to ANSI standards (maximum height = 2.2 inches, including covers). You can program any combination of these plates and vial holders for automated sample processing. Samples are loaded into the sample manager via the front door or the optional sample organizer,
which transfers samples back and forth between the two instruments. The sample manager can maintain samples at any temperature between 4 and 40 C (39.2 to 104 F) in 25 C (77 F) or less ambient conditions.
PDA detector

The PDA (photodiode array) optical detector is an ultraviolet/visible light (UV/Vis) spectrophotometer that operates between 190 and 500 nm. The detector offers two flow cell options. The analytical flow cell, with a volume of 500 nanoliters and a pathlength of 10 mm, and the high sensitivity flow cell, with a volume 2.4 microliters and a 25 mm pathlength, both utilize the Waters patented light-guiding flow cell technology.
High temperature column heater

The high temperature (HT) column heater is modular, and its footprint is identical to that of the sample manager. The column heaters front compartment can accommodate any Waters column up to 4.6 mm ID and 150 mm long. The column rests in a U-shaped tray that swivels outward to receive the column from either side. The high temperature column heater heats the column compartment to any temperature from 5 C (9 F) above ambient to 90 C (194 F). A film element insulated to minimize power consumption and facilitate thermal stability is attached to the tray and produces heat. A passive column stabilizer, inside the tray, reduces sensitivity to ambient temperature swings and minimizes bandspreading.


Manufacturer's Specifications:

Solvent Manager



Number of solvents

Up to four, in any combination of two:

A1 or A2 and B1 or B2.

Solvent conditioning

Vacuum degassing (six-channel): one channel per solvent, and two channels for sample manager wash solvents.

Settable flow rate range

0.001 to 2.000 mL/min, in 0.001 mL increments

Gradient profiles

Eleven gradient curves [including linear, step (2), concave (4), and convex (4)] Wet prime Automatic.



Maximum operating pressure

103,421 kPa (1034 bar, 15,000 psi) up to 1 L/min, 62,053 kPa (621 bar, 9000 psi) up to 2 mL/min

Composition accuracy

0.5% absolute (full scale) from 5 to 95% from 0.50 to 2.00 mL/mina

Composition precision

0.15% RSD or 0.04 min SD

Flow accuracy

1.0% at 0.5 mL/min

Sample Manager



Number of SBS/ANSI sample plates

Total of two plates, expandable to up to 22 plates with optional sample organizer.

Maximum of 22 microtiter plates, 11 intermediate depth plates, or 8 deep-well (or 2 mL vial) plates:

96 and 384 microtiter plates

48-position 2 mL vial plates

48-position 0.65 mL micro-centrifuge tube plates

24-position 1.5 mL micro-centrifuge tube plates

Maximum sample capacity

768 in two 384-well plates; expandable to up to 8,448 samples with optional sample organizer

Injection volume range

0.1 to 50 L, in 0.1 L increments,

partial or full loop mode, 10 L loop is.

standard; 1, 2, 5, 20, and 50 L loops



Sample temperature control

4 to 40 C, programmable in 0.1 C increments

Minimum sample required.

5 L residual volume at a needle offset of 0, or 22 L at the preset 2 mm needle offset.

Column Heater



Columns accepted.

Any up to 4.6 mm ID and 150mm long

Temperature range

5 above ambient to 65C (9 above ambient to 194F)

PDA Detector



Wavelength Range

190-500 nm

Flow Cell Options

Analytical Cell 500 nanoliters, 10 mm pathlength

High Sensitivity Cell 2.4 microliters, 25mm pathlength

Specifications:
Standard
Metric
Manufacturer Name
Waters
 

Serial Number:
C09UPD 538M
C09UPD 538M

Model:
Acquity Classic
Acquity Classic


Dimensions:
Standard
Metric

Overall:
31.00 x 18.00 x 43.00 IN - 210.00 LBS
787.40 x 457.20 x 1092.20 mm - 95.26 kg

Disclaimer

This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in

CA

This equipment is subject to a removal and loading charge.


The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

Please be aware that weights and dimensions of equipment provided on EquipNet’s listings are estimates and can vary from actual weights and size. Sellers estimates are often not precise especially when equipment was installed versus prepped for shipment. As such, please do not fully rely on the accuracy of this information in EquipNet’s listings for shipping quotes and/or user size requirements.

Any license associated with this equipment is non-transferable.

Customers who viewed this item also viewed this