EquipNet, Inc.
Login/Register  |  Sell Equipment  |  About  |  Contact  | 
EquipNet.com Negotiated Sales of Used Equipment Industrial Equipment Auctions Technology Asset Management Services Equipment and Machinery Appraisals and Valuations Asset Management Services My EquipNet Used Industrial Equipment Blog
Search for Equipment


Packaging Equipment    Horizontal Form Fill Seal Machines    188420 DOYEN FOUR LANE, INTERMITTENT MOTION, MULTILAYER TTS--CONVERTING AND POUCHING MACHINE
DOYEN FOUR LANE, INTERMITTENT MOTION, MULTILAYER TTS--CONVERTING AND POUCHING MACHINE
Rate listing info and photo quality Why?

Not rated yet
Listing #188420

DOYEN FOUR LANE, INTERMITTENT MOTION, MULTILAYER TTS--CONVERTING AND POUCHING MACHINE


Best Offer Seller's Acceptable Currency

All offers are submitted in Seller's Acceptable Currency

Equipment Description:

  • One Doyen Multilayer TTS Converting and Four Side Seal Pouching machine. The machine will be supplied as detailed below, capable of producing and packaging your Multilayer Laminate Transdermal Patch devices in four lane configuration, in the package as specified. Tooling for one single product and pack sizes has been included in the price listed below. The base machine will be adaptable to accommodate the options specified in this proposal.
  • Omron PLC control system, GMP designed and CE compliant
  • The number of packages produced by the machine per minute is governed primarily by the number of lanes and the materials used. The expected speed for this project will be 120 packs per minute, based on a machine speed of 30 cycles per minute, subject to trials using your product and material samples
  • Product Description Product Profile Sizes Cream Volume(g) Water Spray Volume (g) Package Sizes(W x L) Production Speed(ppm) 40cm2 Device 83.8mm x 61mm (ellipse) 0.35 0.30 145mm x 101mm 120 Note: Dispense volume tolerance – ± 3% to be confirmed after receipt of samples Device Description: 6-layer, oval Transdermal Patch with central reservoir. Materials: Top cover film 83.8 x 61mm (ellipse) Heating pod 52 x 36mm (ellipse) Skin adhesive film 83.8 x 61mm (ellipse) Heat sealable film 63 x 40mm (ellipse) Nonwoven film 50 x 25mm (ellipse) HDPE tray 83.8 x 61mm (ellipse) with 10cm2 reservoir Cream: (viscosity 50,000 – 75,000 cP) Packaging Film: Grade 92039-92G PET/INK/ADH/35G, FOIL/ADH/100G PE Pack Description: Destructible style four side seal pouch Perforated corner fold (CR requirement)

  • Disclaimers:

    This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in United Kingdom.


    The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

    Equipment Specifications:

    ManufacturerDoyens
    ModelTTS
    Spare/Change Partsyes
    Estimated Shipping Weight27500
    Length57 FT
    Width7 FT
    Height9 FT

    Why we recommend inspection Why we recommend inspection Print Version Print Version Conversion Tools Conversion Tools
    Currency Calculator Currency Calculator Email this page to a colleague Email this page to a colleague


    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson & Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, Oxford Science Park and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, Oxford Science Park, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and Oxford Science Park
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson &Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, Oxford Science Park and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, Oxford Science Park, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and Oxford Science Park
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    I acknowledge these conditions and would like to proceed with a preliminary offer