EquipNet, Inc.
Login/Register  |  Sell Equipment  |  About  |  Contact  | 
EquipNet.com Negotiated Sales of Used Equipment Industrial Equipment Auctions Technology Asset Management Services Equipment and Machinery Appraisals and Valuations Asset Management Services My EquipNet Used Industrial Equipment Blog
Search for Equipment


Processing Equipment    Fluid Bed Dryers    245883 Glatt Fluid Bed Dryer Model GPCG 300
Glatt Fluid Bed Dryer Model GPCG 300
Rate listing info and photo quality Why?

Not rated yet
Listing #245883

Glatt Fluid Bed Dryer Model GPCG 300

EquipNet Tag #245883-1-11, 245883-2-11

$150,000.00 Seller's Acceptable Currency

All offers are submitted in Seller's Acceptable Currency

Equipment Description:

Glatt GPCG 300 Fluid Bed Dryer/Granulator/Coater/dryer, bottom spray, 2 Bar

Fluid bed processing involves drying, cooling, agglomeration, granulation, and coating of particulate materials. It is ideal for a wide range of both heat sensitive and non-heat sensitive products. Uniform processing conditions are achieved by passing a gas (usually air) through a product layer under controlled velocity conditions to create a fluidized state.

In fluid bed drying, heat is supplied by the fluidization gas, but the gas flow need not be the only source. Heat may be effectively introduced by heating surfaces (panels or tubes) immersed in the fluidized layer.

  • Equipment S/N 4232
  • Manufacture Late 1980's
  • System upgraded Yr 2001
  • Content Product container:1.6 cubic meter
  • Steam consumption: 409 kg/h
  • Steam pressure required: 3 bar
  • Compressed air pressure 6 bar
  • Total power consumption 80 kw
  • Voltage: 460V
  • Frequency 60Hz

    •Unit Consists of the Following:
    •Machine Tower
    •Post Hoist Device
    •PLC Control System & HMI System
    •Two (2) 46" Wurster Container Columns Insert for Coating Fine Particles
  • Tilting bottom section with Stainless steal bottom sieve, a spray manifold that includes 7 Spray Nozzles
  • Each spray nozzles is 6.9 inches from the base of the nozzle tip
  • Nozzle tip inner diameter is 0.119 inches
  • Product contact surfaces were manufactures of 304 Stainless Steel polished
  • Inlets and exhaust air ducts are each equipped with an explosion proof, quick action stop valve(QASV)
  • Includes Product Filter Shaker Assembly of two 60 mesh polyester filter located in expansion chamber

    Control System Specifications
  • Control System: Modicon PLC
  • Model: Quatum Series 140 CPU
  • OIT with Intellution FIX 32 software
  • Windows NT Platform
  • Security: FIX & WINDOWS NT

  • Disclaimers:

    This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in Puerto Rico.


    The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

    Equipment Specifications:

    ManufacturerGlatt
    YearUpgraded 2001
    ModelGPGC 300/500
    Serial Number4232
    Capacity Size300
    Estimated Shipping Weight10000 LBS
    Length8 FT
    Width8 FT
    Height24 FT
    Voltage480 VOLTS
    Frequency50/60 HERTZ
    Phase3
    Recommended Packaging FormCUSTOM

    Why we recommend inspection Why we recommend inspection Print Version Print Version Conversion Tools Conversion Tools
    Currency Calculator Currency Calculator Email this page to a colleague Email this page to a colleague


    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson & Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, Merck - MMD - Las Piedras (MSD) (Old SP) and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, Merck - MMD - Las Piedras (MSD) (Old SP), and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and Merck - MMD - Las Piedras (MSD) (Old SP)
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson &Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, Merck - MMD - Las Piedras (MSD) (Old SP) and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, Merck - MMD - Las Piedras (MSD) (Old SP), and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and Merck - MMD - Las Piedras (MSD) (Old SP)
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    I acknowledge these conditions and would like to proceed with a preliminary offer