EquipNet, Inc.
Login/Register  |  Sell Equipment  |  About  |  Contact  | 
EquipNet.com Negotiated Sales of Used Equipment Industrial Equipment Auctions Technology Asset Management Services Equipment and Machinery Appraisals and Valuations Asset Management Services My EquipNet Used Industrial Equipment Blog
Search for Equipment


MRO Equipment    Probes    130787 Lot of (3) Unused Endress & Hauser TR-24 Temperature Probe
Lot of 3 Unused Endress & Hauser TR24 Temperature Probe
Rate listing info and photo quality Why?

1 ratings
Listing #130787

Lot of (3) Unused Endress & Hauser TR-24 Temperature Probe


€420.00 Seller's Acceptable Currency

All offers are submitted in Seller's Acceptable Currency

Equipment Description:

Lot of (3) Unused Endress & Hauser TR-24 Temperature Probe. The model is TR-24-EA2BXC3000. The probe is 14" long. The Omnigrad T TR 24 temperature sensor is made up of a measurement probe and a housing (head), which may contain a transmitter or the terminals on the ceramic block for electrical connection. The sensor is manufactured according to standards DIN 43729 (housing) and 43735 (probe) and can therefore guarantee a good adaptability to the most common industrial processes. The measurement probe consists of a (replaceable) insert in mineral oxide with a diameter of 3 or 6 mm. The TR 24 can be fitted onto the plant (tube or tank) through the use of a compression fitting, which can be chosen from the most common models (see section "Structure of the components"), or it can be inserted into a thermowell The required type of output signal can be obtained by choosing the correct head-mounted transmitter. Endress+Hauser supplies "state-of-the-art" transmitters (the iTEMP® series) built in 2-wire technology and with 4…20 mA output signal, HART® or PROFIBUS-PA®. All of the transmitters can be easily programmed using a personal computer through the ReadWin® 2000 public domain software (for transmitters 4…20 mA and HART®) or the Commuwin II software (for PROFIBUS- PA® transmitters). The HART® transmitters can also be programmed with the hand-held operating module DXR 275 (Universal HART® Communicator). A PCP (4…20 mA, TMT 180) model with enhanced accuracy is available. In the case of PROFIBUS-PA® transmitters, E+H recommends the use of PROFIBUS® dedicated connectors. The Weidmüller type (Pg 13.5 - M12) is provided as a standard option. For detailed information about transmitters, please refer to the relevant documentation (refer to the TI codes at the end of the document). If a head-mounted transmitter is not employed, the sensor probe can be connected through the terminal block to a remote converter The Omnigrad T TR 24 thermometers can be mounted on pipes, vessels or other plant parts that may be necessary, by means of compression junctions or thermowells. The absence of the extension neck (situated between the process connection and the head) may expose the housing to overheating. To ensure that the head temperature does not exceed the limit values defined in paragraph "Operating conditions", refer to figure 3. In the case of ATEX-certified components (transmitter, insert), please refer to the relevant documentation (refer to the code at the end of this document). Immersion depth may have an effect on the accuracy of the measurement. If the immersion is too low, an error may be generated in the temperature recorded due to the lower temperature of the process fluid near to the walls and heat transfer, which takes place through the sensor stem. The incidence of such an error can be not negligible if there is a big difference between the process temperature and the ambient temperature. To avoid measurement errors of this kind, it is advisable to set an immersion length (L) of at least 50÷70 mm (without thermowell).

Disclaimers:

This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in Italy.


The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

Equipment Specifications:

ManufacturerEndress & Hauser
ModelTR-24
Estimated Shipping Weight0 LBS

Why we recommend inspection Why we recommend inspection Print Version Print Version Conversion Tools Conversion Tools
Currency Calculator Currency Calculator Email this page to a colleague Email this page to a colleague


Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
2. You must agree to Johnson & Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
  1. Insurance Certificate in name of buyer; buyer is an end user
  2. General/product liability meets limits required for assets being purchased
  3. Worker’s compensation liability meets required limit
  4. It is agreed that JJSI, Chemtura Corporation - Pedrengo, Italy and its affiliates are included as Additional Named Insureds
  5. Waiver of subrogation applies in favor of JJSI, Chemtura Corporation - Pedrengo, Italy, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
  6. Policy is effective at time of transaction and should be valid for at least one year
  7. Certificate holder is JJSI and Chemtura Corporation - Pedrengo, Italy
  8. Policy includes language that J&J will be notified upon cancellation or expiration
EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
2. You must agree to Johnson &Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
  1. Insurance Certificate in name of buyer; buyer is an end user
  2. General/product liability meets limits required for assets being purchased
  3. Worker’s compensation liability meets required limit
  4. It is agreed that JJSI, Chemtura Corporation - Pedrengo, Italy and its affiliates are included as Additional Named Insureds
  5. Waiver of subrogation applies in favor of JJSI, Chemtura Corporation - Pedrengo, Italy, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
  6. Policy is effective at time of transaction and should be valid for at least one year
  7. Certificate holder is JJSI and Chemtura Corporation - Pedrengo, Italy
  8. Policy includes language that J&J will be notified upon cancellation or expiration
EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
I acknowledge these conditions and would like to proceed with a preliminary offer