EquipNet, Inc.
Login/Register  |  Sell Equipment  |  About  |  Contact  | 
EquipNet.com Negotiated Sales of Used Equipment Industrial Equipment Auctions Technology Asset Management Services Equipment and Machinery Appraisals and Valuations Asset Management Services My EquipNet Used Industrial Equipment Blog
Search for Equipment


Packaging Equipment    Fillers    Pressure Fillers    282698 Unused JDA Progress Pressure Filler Model New
Unused JDA Progress Pressure Filler Model New
Rate listing info and photo quality Why?

1 ratings
Listing #282698

Unused JDA Progress Pressure Filler Model New

EquipNet Tag #0000000000

$8,950.00 Seller's Acceptable Currency

All offers are submitted in Seller's Acceptable Currency

Equipment Description:

  • New 4 Head Expandable Pressure Overflow Filler, Model PF 3000
  • This is an expandable pressure-overflow filler, with semi-automatic inline filling machine: Construction Features: 304 Stainless Steel Heavy-Duty Stainless Steel welded C Frame, 20 Gallon Stainless Steel overflow tank, Stainless Steel cover for overflow tank, 16 hose 304 Stainless Steel feeding manifold, all contact parts are Stainless Steel, sanitary, Teflon, viton and hoses per your requirements, calibrated guide for fast height changeovers, machine mounted on 4 heavy duty casters. Leveling of machine by 1 inch 304 Stainless Steel leveling screws. 8’ Long U-channel for container movement. Special seals and hoses can be ordered (for an additional cost) Control Panel Features: frequency control drive for pump speed, acceleration and deceleration, front panel filling time adjustment trough Omron Timer, front panel start and emergency STOP for easy access, front panel nozzle code for changing nozzle quantities, expandable to 16 nozzles to increase speed, operator foot switch start cycle control. Main components features: 96 gallon per minute, 1 Hp, 3 phase, 316 Stainless Steel centrifugal pump, hardened Stainless Steel calibrated shafts with linear bearings for nozzle rack movement smoothness and durability, 8” stroke air cylinder, 316L Stainless Steel sanitary check valve mounted on pump, and hand wheel and shaft mounted stoppers for height and stroke adjustment. Standard features: nozzle spacing fully adjustable through top screw, container height adjustment from 1 ½” to 16 inches high, nozzle stroke adjustments from 0 to 8 inches, will work with plastic or glass containers, no change parts needed for various types of containers, air filter-regulator and safety lockout valve included. Electric and pneumatic requirements: 110 volts, 60 Hz, 15 Amps, 5 CFM @ 80 PSI.

  • Disclaimers:

    This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in the USA.


    The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

    Equipment Specifications:

    ManufacturerJDA Progress
    Year2010
    ModelNew
    Product Sizing1oz to 16oz
    Products Runcreams, gels, and liquids
    Estimated Shipping Weight1000 LBS
    Length12 FT
    Width4 FT
    Height5 FT
    Recommended Packaging FormCUSTOM PALLET

    Why we recommend inspection Why we recommend inspection Print Version Print Version Conversion Tools Conversion Tools
    Currency Calculator Currency Calculator Email this page to a colleague Email this page to a colleague


    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson & Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, Charleston and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, Charleston, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and Charleston
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    Congratulations! You have an opportunity to purchase equipment from Johnson and Johnson, one of the largest healthcare companies. Please understand that in order to purchase equipment from this company, you will need to meet certain criteria. The criteria that all buyers need to meet are as follows:
    1. You must be the end user of the equipment being purchased and have intentions to install it for your own use.
    2. You must agree to Johnson &Johnson’s terms of sale, by submitting a signed sale agreement (paper, not electronic). To See The Sales Agreement Click Here
    3. You will need to submit an insurance certificate which reflects certain insurance information outlined below:
    1. Insurance Certificate in name of buyer; buyer is an end user
    2. General/product liability meets limits required for assets being purchased
    3. Worker’s compensation liability meets required limit
    4. It is agreed that JJSI, Charleston and its affiliates are included as Additional Named Insureds
    5. Waiver of subrogation applies in favor of JJSI, Charleston, and its affiliates with respects to General Liability, Product Liability and Workers Compensation where agreed to by contract prior to date of loss
    6. Policy is effective at time of transaction and should be valid for at least one year
    7. Certificate holder is JJSI and Charleston
    8. Policy includes language that J&J will be notified upon cancellation or expiration
    EquipNet recognizes that these requirements may be different to previous transactions with EquipNet. We are here to help with any questions you may have as you complete this purchase. Please feel free to contact your EquipNet Sales Representative or the Johnson and Johnson Project Manager, Jeff Turok. Jeff’s number is +1.888.371.6555 x2121 and email is jturok@EquipNet.com.
    I acknowledge these conditions and would like to proceed with a preliminary offer