Equipment Description
BioTek Instruments Synergy Neo2 Multi-Mode Reader Fluorescence Measuring Equipment

Used for less than a year, we have a well maintained Synergy Neo2 Multi-Mode Reader With Plate Loader

Synergy™ Neo2 Multi-Mode Reader is designed for the screening laboratory, with speed and ultra-high performance. Variable bandwidth quad monochromators, sensitive high transmission filter-based optics, laser TRF and up to 4 PMTs provide ultra-fast measurements with excellent results. For walk-away automation and high throughput, BioStack Neo is the fastest on the market, and the barcode-labeled filter cubes help streamline workflows and limit errors. Synergy Neo2 features BioTek’s patented Hybrid Technology™, with its independent optical paths that ensure uncompromised performance in all detection modes. Advanced environmental controls, including CO2 /O2 control, incubation to 65 °C and variable shaking support live cell assays; cell-based detection is optimized with direct bottom illumination. Gen5 Software offers complete reader control, powerful data analysis, and automation and LIMS integration.

Features:

  • Patented Hybrid Technology™ with independent filter and monochromator-based optics
  • Ultra-fast plate processing speeds with multiple PMT detectors
  • Two lasers: Laser for TRF, TR-FRET and laser-based Alpha detection
  • High-performance filters for sensitivity
  • Variable bandwidth scientific quad monochromators for optimal sensitivity and flexibility
  • Controlled environment and direct bottom detection for live cell assays
  • Gen5 software for complete control and integration into automation and LIMS

    Links:
    https://www.biotek.com/products/detection-multi-mode-microplate-readers/synergy-neo2-hybrid-multi-mode-reader/

    https://www.biotek.com/products/literature-request.html?lit=11296&returnProduct=11155&returnPage=overview

    Technical Details: General Detection mode: UV-Vis Abs., FL, Lum., FP, TRF, laser TRF, Alpha Microplate types: 6- to 1536-well plates Other labware: Petri and cell culture dishes; Take3 Micro-Volume Plates Temperature control: 4-Zone incubation to 65 °C with Condensation Control™ +0.2 °C at 37 °C Shaking: Linear, orbital, double-orbital Software: Gen5™ Microplate Reader and Imager Software Gen5 Secure for 21 CFR Part 11 compliance (option) Automation: BioStack and 3rd party automation compatible BioSpa™ 8 Automated Incubator compatible CO2 and O2 control (option): Range: 0 - 20% (CO2 ); 1 - 19% (O2 ) Control Resolution: + 0.1% (CO2 and O2 ) Stability: +0.2% at 5% CO2 ; +0.2%at 1% O2 CO2 /O2 or CO2 -only controllers are available Barcode reader: 1D and 2D camera-based scanner Absorbance Light source: Xenon flash lamp Detector: Photodiode Wavelength selection: Monochromator Wavelength range: 230 nm to 999 nm, in 1 nm increments Bandwidth (bandpass): 2 nm (230 - 285 nm); 4 nm (>285 nm) Wavelength accuracy: ±2 nm Wavelength precision: ±0.2 nm Dynamic range: 0 - 4.000 OD Resolution: 0.0001 OD Pathlength correction: Yes, via Gen5 software Accuracy: <1% at 2.0 OD; <3% at 3.0 OD Linearity: <1% from 0 to 3.0 OD Repeatability: <0.5% at 2.0 OD Stray light: 0.03% at 230 nm Reading speed (kinetic*): 96 well: 6 seconds 384 well: 11 seconds 1536 well: 25 seconds Fluorescence Intensity Light source: Xenon flash lamp Detector: Dual top PMTs Single top PMT (option) Low noise PMT (bottom filter system) Red shifted PMT (top/bottom monochromator system) Wavelength selection: Quad monochromators (top/bottom) Filters (top/bottom) Wavelength range: Monochromators: 250-700 nm, 850 nm option Filters (dual PMT): 200-700 nm, 850 nm option Monochromator bandwidth: Variable, from 3 to 50 nm in 1 nm increments Dynamic range: 7 decades Sensitivity: Filters: Fluorescein 0.2 pM (4 amol/well, 20 µL, 384-well low volume plate) - top Fluorescein 1 pM (10 amol/well, 10 µL, 1536-well plate) - top

    Sensitivity: Quad monochromators: Fluorescein 2 pM (40 amol/well, 20 µL, 384-well low volume plate) - top Fluorescein 2.5 pM (0.25 fmol/well, 100 µL, 384-well plate) - bottom Reading speed (kinetic): 96 well: 6 seconds; 384 well: 11 seconds; 1536 well: 25 seconds Luminescence Wavelength range: 300 - 700 nm Sensitivity: 5 amol (filters); 10 amol (monos) Fluorescence Polarization Light source: Xenon flash Detector: Dual PMT or single PMT (option) Wavelength selection: Filters Wavelength range: 280 - 850 nm Sensitivity: 1 mP standard deviation at 1 nM fluorescein (384-well low volume plate) 1.5 mP standard deviation at 1 nM fluorescein (1536-well plate) Time-Resolved Fluorescence Light source: Xenon flash; 337 nm laser Detector: Dual PMT or single PMT (option); Dual PMT (337 nm laser) Wavelength selection: Filters Wavelength range: Monochromators: 250 - 850 nm Sensitivity: With TRF laser: 5 fM (384-well low volume plate) With Xenon flash lamp: 40 fM (384-well low volume plate) Alpha Detection Light source: 100 mW 680 nm laser Detector: PMT Wavelength selection: Filters (top) Sensitivity: 100 amol LCK peptide (384-well low volume plate) Read speed: 96 well: 30 seconds 384 well: 1 minute 50 seconds 1536 well: 7 minutes 20 seconds Reagent Injectors Supported detection modes: All modes Number: 2 syringe pumps Supported labware: 6- to 384-well plates Dead volume: 1.1 ml, with back flush Dispense volume: 5 - 1,000 µL in 1 µL increments Dispense accuracy: ±1 µL or 2% Dispense precision: =2% at 50 - 200 µL Physical Characteristics Power: 250 Watts maximum consumption

    Dimensions: Without TRF laser: 15.4” W x 20.7” D x 16.1” H (39.2 x 52.5 x 40.8 cm) With TRF laser: 15.4” W x 24.2” D x 16.1” H (39.2 x 61.4 x 40.8 cm) Weight: Without TRF laser: 78 lbs. (35.4 kg) With TRF laser: 100 lbs. (45.3 kg)

    Regulatory CE and TUV marked, RoHS compliant. In Vitro Diagnostic use models are available. Technical details are subject to change.

    Optional Accessories:

  • CO2 /O2 Gas Controller Module
  • BioStack™ Microplate Stacker (BioStack 4 and BioStack Neo configurations)
  • BioSpa™ 8 Automated Incubator
  • Dual Reagent Injector Module
  • Take3™ Micro-Volume Plate
  • Gen5™ Secure for 21 CFR Part 11 Compliance
  • Fluorescence, Luminescence, and Absorbance Test Plates C

  • Specifications:
    Standard
    Metric
    Manufacturer Name
    BioTek Instruments
     

    Year:
    2021
    2021

    Model:
    Synergy Neo2 Multi-Mode Reader
    Synergy Neo2 Multi-Mode Reader

    Voltage:
    120 VOLTS
    120 VOLTS

    Frequency:
    50/60 HERTZ
    50/60 HERTZ

    Phase:
    1
    1

    Recommended Packaging Form:
    CUSTOM PALLET
    CUSTOM PALLET


    Dimensions:
    Standard
    Metric

    Overall:
    3 x 3 x 3 FT - 300 LBS
    91.44 x 91.44 x 91.44 cm - 136.08 kg

    Disclaimer

    This lot is being sold "as is, where is". We recommend that you contact an EquipNet sales representative to set up your own inspection. This item is located in

    CA

    This equipment is subject to a removal and loading charge.


    The written description provided for this equipment is EXACTLY what you will receive if you opt to purchase this listing. Any items that are not in the description but appear in the visual representations of this listing will not be included in the sale. Photos and video are provided just as references and to give a general sense of condition.

    Please be aware that weights and dimensions of equipment provided on EquipNet’s listings are estimates and can vary from actual weights and size. Sellers estimates are often not precise especially when equipment was installed versus prepped for shipment. As such, please do not fully rely on the accuracy of this information in EquipNet’s listings for shipping quotes and/or user size requirements.

    Any license associated with this equipment is non-transferable.

    Customers who viewed this item also viewed this