Número do item 907797

Equipamento de Medição por Fluorescência BioTek Instruments Synergy Neo2 Multi-Mode Reader


Entre em contato

Moeda Aceitável de Vendedores:

$85,000.00 USD

Fazer uma oferta

Localização:  CA, Estados Unidos

Nível de Remoção:  

Por que recomendamos visita aos equipamentos?

*Todas as ofertas são enviadas em moeda dos vendedores

Não encontrou o que você está procurando? Nós podemos encontrar para você




Descrição do equipamento
BioTek Instruments Synergy Neo2 Multi-Mode Reader Fluorescence Measuring Equipment

Used for less than a year, we have a well maintained Synergy Neo2 Multi-Mode Reader With Plate Loader

Synergy™ Neo2 Multi-Mode Reader is designed for the screening laboratory, with speed and ultra-high performance. Variable bandwidth quad monochromators, sensitive high transmission filter-based optics, laser TRF and up to 4 PMTs provide ultra-fast measurements with excellent results. For walk-away automation and high throughput, BioStack Neo is the fastest on the market, and the barcode-labeled filter cubes help streamline workflows and limit errors. Synergy Neo2 features BioTek’s patented Hybrid Technology™, with its independent optical paths that ensure uncompromised performance in all detection modes. Advanced environmental controls, including CO2 /O2 control, incubation to 65 °C and variable shaking support live cell assays; cell-based detection is optimized with direct bottom illumination. Gen5 Software offers complete reader control, powerful data analysis, and automation and LIMS integration.

Features:

  • Patented Hybrid Technology™ with independent filter and monochromator-based optics
  • Ultra-fast plate processing speeds with multiple PMT detectors
  • Two lasers: Laser for TRF, TR-FRET and laser-based Alpha detection
  • High-performance filters for sensitivity
  • Variable bandwidth scientific quad monochromators for optimal sensitivity and flexibility
  • Controlled environment and direct bottom detection for live cell assays
  • Gen5 software for complete control and integration into automation and LIMS

    Links:
    https://www.biotek.com/products/detection-multi-mode-microplate-readers/synergy-neo2-hybrid-multi-mode-reader/

    https://www.biotek.com/products/literature-request.html?lit=11296&returnProduct=11155&returnPage=overview

    Technical Details: General Detection mode: UV-Vis Abs., FL, Lum., FP, TRF, laser TRF, Alpha Microplate types: 6- to 1536-well plates Other labware: Petri and cell culture dishes; Take3 Micro-Volume Plates Temperature control: 4-Zone incubation to 65 °C with Condensation Control™ +0.2 °C at 37 °C Shaking: Linear, orbital, double-orbital Software: Gen5™ Microplate Reader and Imager Software Gen5 Secure for 21 CFR Part 11 compliance (option) Automation: BioStack and 3rd party automation compatible BioSpa™ 8 Automated Incubator compatible CO2 and O2 control (option): Range: 0 - 20% (CO2 ); 1 - 19% (O2 ) Control Resolution: + 0.1% (CO2 and O2 ) Stability: +0.2% at 5% CO2 ; +0.2%at 1% O2 CO2 /O2 or CO2 -only controllers are available Barcode reader: 1D and 2D camera-based scanner Absorbance Light source: Xenon flash lamp Detector: Photodiode Wavelength selection: Monochromator Wavelength range: 230 nm to 999 nm, in 1 nm increments Bandwidth (bandpass): 2 nm (230 - 285 nm); 4 nm (>285 nm) Wavelength accuracy: ±2 nm Wavelength precision: ±0.2 nm Dynamic range: 0 - 4.000 OD Resolution: 0.0001 OD Pathlength correction: Yes, via Gen5 software Accuracy: <1% at 2.0 OD; <3% at 3.0 OD Linearity: <1% from 0 to 3.0 OD Repeatability: <0.5% at 2.0 OD Stray light: 0.03% at 230 nm Reading speed (kinetic*): 96 well: 6 seconds 384 well: 11 seconds 1536 well: 25 seconds Fluorescence Intensity Light source: Xenon flash lamp Detector: Dual top PMTs Single top PMT (option) Low noise PMT (bottom filter system) Red shifted PMT (top/bottom monochromator system) Wavelength selection: Quad monochromators (top/bottom) Filters (top/bottom) Wavelength range: Monochromators: 250-700 nm, 850 nm option Filters (dual PMT): 200-700 nm, 850 nm option Monochromator bandwidth: Variable, from 3 to 50 nm in 1 nm increments Dynamic range: 7 decades Sensitivity: Filters: Fluorescein 0.2 pM (4 amol/well, 20 µL, 384-well low volume plate) - top Fluorescein 1 pM (10 amol/well, 10 µL, 1536-well plate) - top

    Sensitivity: Quad monochromators: Fluorescein 2 pM (40 amol/well, 20 µL, 384-well low volume plate) - top Fluorescein 2.5 pM (0.25 fmol/well, 100 µL, 384-well plate) - bottom Reading speed (kinetic): 96 well: 6 seconds; 384 well: 11 seconds; 1536 well: 25 seconds Luminescence Wavelength range: 300 - 700 nm Sensitivity: 5 amol (filters); 10 amol (monos) Fluorescence Polarization Light source: Xenon flash Detector: Dual PMT or single PMT (option) Wavelength selection: Filters Wavelength range: 280 - 850 nm Sensitivity: 1 mP standard deviation at 1 nM fluorescein (384-well low volume plate) 1.5 mP standard deviation at 1 nM fluorescein (1536-well plate) Time-Resolved Fluorescence Light source: Xenon flash; 337 nm laser Detector: Dual PMT or single PMT (option); Dual PMT (337 nm laser) Wavelength selection: Filters Wavelength range: Monochromators: 250 - 850 nm Sensitivity: With TRF laser: 5 fM (384-well low volume plate) With Xenon flash lamp: 40 fM (384-well low volume plate) Alpha Detection Light source: 100 mW 680 nm laser Detector: PMT Wavelength selection: Filters (top) Sensitivity: 100 amol LCK peptide (384-well low volume plate) Read speed: 96 well: 30 seconds 384 well: 1 minute 50 seconds 1536 well: 7 minutes 20 seconds Reagent Injectors Supported detection modes: All modes Number: 2 syringe pumps Supported labware: 6- to 384-well plates Dead volume: 1.1 ml, with back flush Dispense volume: 5 - 1,000 µL in 1 µL increments Dispense accuracy: ±1 µL or 2% Dispense precision: =2% at 50 - 200 µL Physical Characteristics Power: 250 Watts maximum consumption

    Dimensions: Without TRF laser: 15.4” W x 20.7” D x 16.1” H (39.2 x 52.5 x 40.8 cm) With TRF laser: 15.4” W x 24.2” D x 16.1” H (39.2 x 61.4 x 40.8 cm) Weight: Without TRF laser: 78 lbs. (35.4 kg) With TRF laser: 100 lbs. (45.3 kg)

    Regulatory CE and TUV marked, RoHS compliant. In Vitro Diagnostic use models are available. Technical details are subject to change.

    Optional Accessories:

  • CO2 /O2 Gas Controller Module
  • BioStack™ Microplate Stacker (BioStack 4 and BioStack Neo configurations)
  • BioSpa™ 8 Automated Incubator
  • Dual Reagent Injector Module
  • Take3™ Micro-Volume Plate
  • Gen5™ Secure for 21 CFR Part 11 Compliance
  • Fluorescence, Luminescence, and Absorbance Test Plates C

  • Especificações:
    Padrão
    Métrico
    Nome do fabricante
    BioTek Instruments
     

    Ano:
    2021
    2021

    Modelo:
    Synergy Neo2 Multi-Mode Reader
    Synergy Neo2 Multi-Mode Reader

    Tensão:
    120 VOLTS
    120 VOLTS

    Frequência:
    50/60 HERTZ
    50/60 HERTZ

    Fase:
    1
    1

    Forma Recomendável da Embalagem:
    PALLET CUSTOMIZADO
    PALLET CUSTOMIZADO


    Dimensões:
    Padrão
    Métrico

    Total:
    3 x 3 x 3 FT - 300 LBS
    91,44 x 91,44 x 91,44 cm - 136,08 kg

    Aviso Legal

    Recomendamos que você entre em contato com a EquipNet para agendar uma visita ao equipamento (19) 3277-1125, [email protected].

    CA

    Quaisquer itens que não estão na descrição, mas aparecem nas representações visuais, não serão incluídos na venda. Remoção, desmontagem, embalagem, seguro e frete: custos de responsabilidade do comprador.


    Quaisquer itens que não estão na descrição, mas aparecem nas representações visuais, não serão incluídos na venda. Remoção, desmontagem, embalagem, seguro e frete: custos de responsabilidade do comprador. Poderão haver requisitos específicos na execução dos serviços dentro da área do vendedor. Poderá ser obrigatória a realização dos serviços somente por empresas que já são homologadas pelo vendedor.

    Pessoas que visualizaram este produto também viram: